| Diversion
Baffles for Wastewater Treating
Custom-designed baffles have specially
sized and placed windows that control flow and circulation
in wastewater treating ponds, to eliminate dead zones,
increase detention time, and improve treatment efficiency.
- Top tension cable is 5/16-inch galvanized
steel aircraft cable sealed in fabric. Stainless-steel
cable is optional.
- Bottom ballast is 3/8-inch galvanized
chain in sealed bottom pocket.
- End tension plate is double 3/16-inch
x 3-inch stainless-steel plate with 3/8-inch stainless-steel
bolts.
- Flow-through windows have rounded
corners, dielectrically sealed and reinforced with
2-inch webbing. Window size is a minimum of 1 sq
ft per 30 gal/min.
- Baffle connections are double-thick
fabric, dielectrically sealed, with stainless-steel
grommets set in 2-inch-wide webbing.
- Flotation is rolled closed-cell polyfoam
with a minimum of 55 lb/cu ft buoyancy. Polyfoam
will not wick water or oil.
- Curtain fabric is 30-oz, reinforced
,coated polyester material that resists wicking,
ultraviolet radiation and extreme temperatures.
Other fabrics available for special applications.
Custom Design
We custom design diversion baffles
for specific wastewater applications. Information
we need includes:
- basin dimensions
- side slope
- maximum flow
- water temperature
- water pH
- type and number of aerators
Click
here to download a Diversion Baffle Worksheet |


|